2 contributor
# vim: ft=sh
function nginx () {
nc -zw2 127.0.0.1 80 || echo "injoignable sur port 80 local"
nc -zw2 paris12.pcf.fr 80 || echo "injoignable sur port 80 distant"
nc -zw2 paris12.pcf.fr 443 || echo "injoignable sur port 443 distant"
}
function core_temp () {
local min=60
local level=("warning" "severe" "danger!")
local step=$(( $(</sys/class/thermal/thermal_zone0/temp) - (min * 1000) ))
if test $step -gt 1; then
# if test $step -gt 5000; then # en été il fait plus chaud, c'est normal que ça monte à 60° régulièrement
step=$((step / 10000))
test $step -le 2 || step=2
echo "${level[step]}: température > $((min + step * 10))°"
fi
}
function core_alim () {
eval $(/opt/vc/bin/vcgencmd measure_volts core)
volt_fmt=${volt/\.}
volt_fmt=${volt_fmt/V}
test $volt_fmt -lt 12000 -o $volt_fmt -gt 15000 && echo "$volt"
}
function clean_swap () {
_turn 2 || return
echo 1 > /proc/sys/vm/drop_caches
if free -m | awk '
/^Swap:/ {
used = $3
}
END {
exit (used > 31)
}
'; then
systemctl stop dphys-swapfile \
&& systemctl stop zram \
&& systemctl start zram \
&& systemctl start dphys-swapfile \
|| echo 'erreur'
fi
}
function mem_pressure () {
local meminfo=($(</proc/meminfo))
local level=(danger severe warning)
local margin=30000
for ((i=0; i<${#meminfo[@]}; i+=3)); do
test ${meminfo[i]} == 'MemAvailable:' && break
done
meminfo[i+2]=$(( ( ${meminfo[i+1]} - $margin ) / 100000 ))
test ${meminfo[i+2]} -ge ${#range[@]} || echo "${level[${meminfo[i+2]}]}: available ${meminfo[i+1]}kB"
}
function printer () {
_turn 24 || return
local min=20
local level=(extreme danger warning info)
local printer=192.168.1.54
local prtMarkerSuppliesMaxCapacity=1.3.6.1.2.1.43.11.1.1.8.1
local prtMarkerSuppliesLevel=1.3.6.1.2.1.43.11.1.1.9.1
local left=$(snmpget -v 1 -c public $printer ${prtMarkerSuppliesLevel}.4)
local full=$(snmpget -v 1 -c public $printer ${prtMarkerSuppliesMaxCapacity}.4)
if test ${full#*:} -ne 0; then
local step=$(((${left#*:}*100/${full#*:})/5))
if test $step -le ${#level[@]}; then
echo "${level[$step]} toner black"
fi
fi
}